Geyser IC · ABB Value Provider / Channel Partner · Measurement & Analytics
ABB Continuous Water Analysis

Dissolved oxygen

From aeration control in wastewater to corrosion monitoring in the steam and water cycle. At lower measuring ranges, sample conditioning and line integrity become part of the measurement.

Dissolved oxygen
From mg/L to sub-ppb

ADS420 · Navigator 500 · AeroStar

ADS420 provides optical DO measurement for wastewater and process water. Navigator ADS550 covers high-purity applications with a dedicated wet section. The new AeroStar Ultra ADS560 measures down to approximately 4 ppb, while AeroStar Ultra Trace ADS565 reaches approximately 0.8 ppb.

When to use it / when to consider alternatives

Practical guidance

Best practice

Installation and maintenance

Best to know

Useful technical details

Models and installed base

Models we support

ABB documentation

ABB datasheets and manuals

Download the documents for your model. Shared manuals, protocols and versions are identified in each document card.

Navigator 500 · ADS550

Documentation for the Navigator analyser with ADS550 wet section and Navigator transmitter.

  • DS/ADS550-EN · Rev. I · 08.2024 · EN
  • OI/ADS550-EN · Rev. I · 05.2018 · EN
Request a quotation

Dissolved oxygen

P&ID / specification

Attach files in your email application after preparing the enquiry.

Geyser IC uses your details to handle this enquiry. Read the privacy notice

Prepare your enquiry, then open it in your email application. Nothing is sent automatically.
Technical FAQ

Frequently asked questions

ADS420 or AeroStar?

ADS420 covers mg/L measurement in aeration and wastewater. AeroStar ADS560/565 is designed for high-purity water and trace DO at ppb/sub-ppb levels.

Does ADS420 need periodic calibration?

ABB describes it as a drift-free optical sensor requiring no routine calibration. Cap condition, cleaning and measurement plausibility must still be checked.

Why is ultra-trace DO much harder to measure?

At ppb levels, slight air ingress, permeable tubing, sample leaks or degassing can affect the reading more than the process itself.

Does the ADS420 optical sensor need flow?

ABB specifies no minimum flow requirement for the measurement principle, but the installation must still provide a representative sample without bubbles.

Where is DO measured in the steam and water cycle?

In condensate, feedwater and cycle points where oxygen affects corrosion and chemistry control; sample conditioning is essential.