LMG200
ABB version optimised for standard conditions, based on KM26 experience with a more focused configuration.
Continuous local indication without pressurised glass or electrical power. The bypass chamber follows the vessel level, and the float magnetically operates the external indicator.

The ABB/K-TEK platform for demanding oil and gas, chemical, petrochemical and power applications. Built to the specified materials, pressure/temperature, density and connections.

ABB version optimised for standard conditions, based on KM26 experience with a more focused configuration.

Dual-chamber system: magnetic indication and guided wave radar in a separate chamber. Designed for greater redundancy, for example in power/feedwater heaters.
Chamber-mounted magnetostrictive transmitter: follows the float magnet and provides 4–20 mA/HART without electronics in contact with the fluid.
Externally mounted magnetically operated switches. They provide adjustable high/low thresholds without adding dedicated process connections.
Size for actual density, pressure and temperature, particularly for interface measurement.
Provide valves and drainage for commissioning and maintenance.
The chamber must be vertical and connected to the vessel so that it follows the actual level.
Design these without obstructing reading or maintenance.
Position and diameter influence equalisation and deposits.
KM26 with LMT200 and switches, or MW05, separates indication, transmission and alarms.
Download the documents for your model. Shared manuals, protocols and versions are identified in each document card.
Separate datasheets for side-mounted KM26S and top-mounted KM26T. Shared KM26 / MW05 / LMG / EC manual.
LMG200 datasheet and LMG family manual, shared with KM26 / MW05 / EC.
Dual-chamber system datasheet, shared mechanical manual and MW05 configuration guide. The associated radar requires the manual for its own version.
Select the HART or FOUNDATION Fieldbus manual for the installed transmitter.
English manual rev. C (08.2024); Italian manual rev. A (01.2016), an earlier edition.
When local indication independent of power is needed and the liquid process is compatible with a chamber and float. Radar and a magnetic indicator can also be used together for redundant measurement.
KM26 is the custom platform for severe conditions and a broad choice of materials/configurations; LMG200 is optimised for standard general-industry applications.
Yes. A typical configuration uses an LMT200 outside the chamber, without direct process contact.
Yes. LMS/MS magnetic switches are mounted externally, and their setpoints can be adjusted without changing the process piping.
Yes, provided the float is designed for the fluid densities and the interface has sufficient ΔSG.
Deposits, solids, crystallisation, extreme viscosity or a chamber not properly equalised with the vessel can impair float movement.