266CSH / 266CST
Compensated flow calculation. Manual for HART communication.
One transmitter can acquire differential pressure, absolute pressure and process temperature simultaneously. 266C models can also use these variables for dynamic flow and compensated-level calculations.
Differential and absolute pressure sensors are integrated into the transmitter. Process temperature is acquired through an external 4-wire Pt100.
Download PDFs for your model. IT or EN identifies the language. Select manuals to match the instrument's communication protocol.
Compensated flow calculation. Manual for HART communication.
Differential pressure, absolute pressure and temperature measurement. HART manual.
Multivariable versions with diaphragm seals.
Accuracy is not the only difference: the transmitter's role within the system changes.
Measure differential pressure, absolute pressure and temperature, and can directly calculate mass flow, standard volume, heat flow and compensated level.
| Model | DP accuracy |
|---|---|
| 266CSH | 0.075% |
| 266CST | 0.04% |
Measure differential pressure, absolute pressure and temperature through an external RTD. The variables are then available to a PLC, DCS or flow computer for external calculations.
| Model | DP accuracy |
|---|---|
| 266JSH | 0.075% |
| 266JST | 0.04% |
Beyond pressure and temperature, calculations can account for density, Reynolds number, discharge coefficient, compressibility and thermal expansion of the pipe and primary element.
In many applications it replaces a DP transmitter, pressure transmitter, temperature transmitter and external calculator, reducing wiring and process penetrations.
ABB integrates equations for numerous standard primary elements and also supports non-standard configurations.
Process temperature is measured through an external 4-wire Pt100. ABB's datasheet specifies an input range of -200 to +850 °C.
ABB specifies the accuracy contribution of the transmitter's Pt100 measuring section as ±0.3 K.
When liquid density changes with temperature, 266C can use process temperature to correct conversion from differential pressure to level.
The platform offers dedicated drum-level configurations, using pressure and temperature for more reliable compensation.
266C multivariable versions with remote diaphragm seals for mass flow and level where process isolation is required.
266J multivariable versions with remote diaphragm seals for differential pressure, absolute pressure and temperature measurement.
Original documents for identifying installed versions. Check the full code and protocol on the nameplate.
Datasheet for differential pressure, absolute pressure and temperature. A dedicated manual is unavailable.
For multivariable applications, include the primary element, fluid and pressure/temperature ranges.
266CST measures differential pressure, absolute pressure and temperature, using them to calculate mass flow, standard volume, heat flow or compensated level directly. 266JST measures these variables and makes them available to an external system.
The functions are the same, but the DP accuracy class differs: 266CSH has 0.075% basic accuracy, while 266CST reaches 0.04%.
Both measure differential pressure, absolute pressure and temperature through an external RTD. Basic accuracy is 0.075% for 266JSH and up to 0.04% for 266JST.
Yes, through an external 4-wire Pt100. ABB specifies a Pt100 input range from -200 to +850 °C, with a transmitter contribution of ±0.3 K.
Yes. Dynamic calculation uses differential pressure, absolute pressure and temperature, and can also compensate for density, Reynolds number, discharge coefficient and primary-element thermal expansion.
ABB provides equations for many DP elements, including orifices, nozzles, Venturi tubes, Pitot probes, wedge elements and configurable non-standard flow sensors.
Yes. The platform supports totalisers and quantities such as mass flow, volume flow and heat flow, with digital or pulse outputs depending on configuration.
Yes. 266C models can be configured for density-compensated level and applications such as steam drum level.
266CRH/CRT and 266JRH/JRT are multivariable versions with remote diaphragm seals, covered on the dedicated Geyser diaphragm-seal transmitter page.